Researchers at the University of Ottawa in Canada have investigated the effects of using an artificial ground reflector in large scale bifacial solar panel in Ground On Grid Solar System and have found it can increase a facility's power generation by up to 4.5%.
"Critically, these reflectors should be placed directly under the solar panels, not between rows, to maximize this benefit," said the research lead author, Mandy Lewis. "These findings are particularly significant in Canada, where snow cover persists for three-to four months of the year in major cities like Ottawa and Toronto, and 65% of the country's vast landmass experiences snow cover for over half the year."
The research team conducted its analysis on a 75 kW bifacial system based on PV Ground Mounting Systems and located at a testing facility of the US Department of Energy's National Renewable Energy Laboratory (NREL) in Golden, Colorado. "We studied a single row of PERC+ modules with a bifaciality factor of 70%," it explained, noting that the testing was performed over 4 months. "Module-level power and weather data were measured at 1-min intervals and right-averaged to obtain 15-min power values."
The scientists utilized an artificial high-albedo, UV-resistant reflector material made of high-density polyethylene (HDPE), provided by Germany-based Solmax Geosynthetics. Its solar-weighted reflectivity reached approximately 70%. They assessed five different reflector configurations: with 100% ground coverage; 50% and 25% ground coverage, both centered on the torque tube; and 50% and 25% ground coverage, both centered in the middle of the open ground between rows.
The performance of the PV system's parts relying on the reflector was compared to that of module rows without the reflector. The modeling presented a root mean square error (RMSE) of 5.4% on an hourly basis and showed an increase in total annual irradiance of 8.6% and an annual energy yield of up to 4.5% when 70% reflective material is added to a single-axis-tracked system. The optimal reflector placement was found to be the one centered directly under the torque tube for all reflector sizes.
Further economic analysis also found the reflector technology can achieve breakeven installed costs of $2.50–4.60 per m2. "Higher breakeven material costs are possible in systems with higher initial LCOE. For example, we found breakeven installed costs of $3.40–6.00/m2 for Seattle, Washington, with 60% reflective material," the academics stressed.
Another research group at the University of Ottawa recently developed a new technique to measure the energy yield of bifacial PV systems. The new scaled rear irradiance (SRI) method purportedly improves IEC measurements by accommodating the effects of different ground covers' spectral albedo in its calculation of the bifacial system's rear-side irradiance.